dc.description.abstractEl proyecto ha marcado un avance tecnológico invaluable para el hospital, posicionándolo a la vanguardia en sistemas de gestión de HVAC con un alto nivel de automatización. La consecución del objetivo principal de implementar un sistema de control HVAC automatizado ha logrado mantener las condiciones ambientales óptimas en los diferentes espacios hospitalarios de manera eficiente. La elección de una arquitectura de control basada en el protocolo BACnet ha facilitado una integración eficiente de todos los subsistemas involucrados, mejorando la coordinación y operación del sistema. El dimensionamiento preciso y la selección de equipos de alta calidad aseguran un funcionamiento confiable y un mantenimiento mínimo del sistema, contribuyendo a su durabilidad. Las exhaustivas pruebas realizadas han verificado la total conformidad de la solución implementada con los requerimientos y especificaciones establecidos, validando la efectividad del sistema en su conjunto. La capacitación impartida al personal del hospital ha sido clave para transferir las habilidades necesarias, garantizando la operación eficiente y sostenibilidad a largo plazo de la solución. El cumplimiento exitoso dentro del cronograma y presupuesto iniciales refleja una ejecución eficiente bajo una gestión de proyectos adecuada. Destaca el trabajo en equipo multidisciplinario entre las áreas de instalaciones, ingeniería clínica y tecnologías de la información, evidenciando la importancia de la colaboración para el éxito del proyecto. En conclusión, el proyecto se erige como un éxito integral, evidenciado en la infraestructura de clase mundial que ahora ostenta el Hospital Llata. Este logro no solo cumple con los objetivos técnicos, financieros y de gestión, sino que también representa un impacto positivo en la calidad de los servicios de salud ofrecidos por la institución.
dc.description.abstractThe project has marked an invaluable technological advancement for the hospital, positioning it at the forefront of HVAC management systems with a high level of automation. The achievement of the main objective—implementing an automated HVAC control system—has successfully maintained optimal environmental conditions across various hospital spaces in an efficient manner. The choice of a control architecture based on the BACnet protocol has enabled efficient integration of all involved subsystems, enhancing system coordination and operation. Precise sizing and the selection of high-quality equipment ensure reliable performance and minimal maintenance, contributing to the system’s durability. Extensive testing has verified full compliance of the implemented solution with the established requirements and specifications, validating the overall effectiveness of the system. The training provided to hospital staff has been key to transferring the necessary skills, ensuring efficient operation and long-term sustainability of the solution. Successful completion within the initial schedule and budget reflects efficient execution under proper project management. The multidisciplinary teamwork among the facilities, clinical engineering, and information technology departments highlights the importance of collaboration for the project’s success. In conclusion, the project stands as a comprehensive success, evidenced by the world-class infrastructure now held by Hospital Llata. This achievement not only meets technical, financial, and management objectives, but also represents a positive impact on the quality of healthcare services provided by the institution.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13028/6697
dc.language.isospa
dc.publisherUniversidad Nacional San Luis Gonzaga.
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectBúsqueda de información
dc.subjectTrabajo en equipo e investigación de campo.
dc.subjectInformation search
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.02.00
dc.titleImplementación de un sistema automatizado de aire acondicionado y ventilación forzada en los servicios de salud del Hospital de Llata, Huánuco
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni21414443
renati.advisor.orcidhtpps://orcid.org/0000-0002-2620-1500
renati.author.dni70379543
renati.discipline713076
renati.jurorRodríguez Chacón, José Carlos
renati.jurorVargas Caritas, Claudio
renati.jurorHernández Henández, Primitivo Bacilio
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttp://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineIngeniería Mecánica Eléctrica
thesis.degree.grantorUniversidad Nacional San Luis Gonzaga. Facultad de Ingeniería Mecánica y eléctrica
thesis.degree.nameIngeniero Mecánico Eléctricista

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Implementación de un sistema automatizado de aire acondicionado y ventilación forzada en los servicios de salud del Hospital de Llata, Huánuco.pdf
Tamaño:
10.77 MB
Formato:
Adobe Portable Document Format
No hay miniatura disponible
Nombre:
ANTIPLAGIO.pdf
Tamaño:
533.24 KB
Formato:
Adobe Portable Document Format
No hay miniatura disponible
Nombre:
Formato de autorización.pdf
Tamaño:
149.59 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.27 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones